Troubleshooting and Fixing an E15 Fault “Gas Valve Error”

On Your Main Eco Compact Boiler

Skip To:

Imagine your Main eco boiler as a superhero, bravely battling cold weather and keeping your home warm and cosy. But just like any superhero, even the boiler can encounter some challenges along the way.

Now, meet the mischievous Gas Valve Gremlin! This little troublemaker loves to play tricks on your boiler by messing with its gas valve. When the Gas Valve Gremlin strikes, your boiler gets confused and displays the E15 fault code.

But fear not! The E15 fault is just your boiler’s way of saying, “Hey, there’s a problem with the gas valve, and I need some help to fix it!” It’s like a superhero distress signal, calling for a professional sidekick to save the day.

The Gas Valve Gremlin may cause the gas valve to get stuck or act up, which disrupts the flow of gas to the boiler. That’s why your boiler needs an engineer’s expertise to swoop in and restore balance to the gas valve, ensuring it opens and closes smoothly, like a well-oiled superhero gadget.

Once the engineer defeats the Gas Valve Gremlin and restores order, your boiler will be back in action, ready to continue its mission of keeping your home warm and toasty. And you can rest easy knowing that the superhero team of your boiler and the engineer have saved the day!

So, the next time you see the E15 fault code on your Main eco boiler, remember the Gas Valve Gremlin and the heroic engineer who will come to the rescue, ensuring your boiler can continue its mission as your home’s trusty heating superhero.

E15 Red Flags!

  • No heating or hot water: The boiler fails to provide heating or hot water when the E15 fault code appears. This sudden loss of functionality is a clear red flag that there may be an issue with the gas valve.
  • Error code display: The E15 fault code itself is a red flag. When the boiler detects a problem with the gas valve, it triggers this specific error code to alert you that something is wrong.
  • Ignition attempts: If you notice that the boiler is repeatedly attempting to ignite but fails to do so, it could be due to a malfunctioning gas valve, which is indicated by the E15 fault code.
  • Unusual noises: A faulty gas valve can sometimes produce unusual noises, such as clicking or hissing sounds. If you hear any strange sounds coming from your boiler, it’s worth investigating further and considering the possibility of a gas valve issue.
  • Gas smell: While not always present, a faint smell of gas around the boiler can be a red flag for a gas valve problem. If you detect the odor of gas, it’s important to take immediate action by turning off the boiler and contacting a professional, as gas leaks can be hazardous.

While the provided information can be attempted by homeowners, fixing the “gas valve error” this often requires a qualified gas engineer, specialized knowledge, and tools. Gas-related issues can be potentially dangerous, so it is crucial to prioritize safety. If you are QUALIFIED and confident in your skills and have experience working with heating systems, you can try the troubleshooting steps cautiously. However, if you are unsure or uncomfortable with handling gas-related repairs, it is best to leave it to the professionals to ensure a safe and accurate resolution.

Check out what your allowed to do:

E15 Troubleshooting Tips:

  1. Inspection: The engineer would start by visually inspecting the gas valve and associated components for any obvious signs of damage or malfunction.
  2. Gas supply check: They would verify the gas supply by checking the gas pressure and ensuring that the gas shut-off valve is fully open. If there are any issues with the gas supply, they would address them accordingly.
  3. Testing the gas valve: The engineer would use appropriate testing equipment to check the functionality of the gas valve. This may involve checking for proper gas flow, measuring voltage or resistance, and ensuring that the valve opens and closes correctly.
  4. Cleaning or replacing the gas valve: Depending on the specific problem identified, the engineer may clean the gas valve if there is any debris or build-up causing obstruction. If the valve is faulty and cannot be repaired, they would replace it with a new one.
  5. System reset: After any necessary repairs or replacements, the engineer would reset the boiler and test its operation to ensure that the Compact E15 error no longer appears and that the gas valve functions correctly.

What can you do as a Homeowner?

Make sure you have electricity to the boiler. Make sure the front screen is on the boiler and the boiler is switched on at the switched fuse.

Make sure the valves on the bottom of the boiler are open (With the Pipe = Open, Across the Pipe = Closed) (Except the Combi Filling loop leave closes). When you have the E15 error code you are mainly looking for the middle valve on this boiler normally has a yellow lever.

Check the boiler has the correct pressure, This is normally 1 bar – 1.5 bar of pressure. 

(Check out our video on how to fill up your main eco compact boiler) if the boiler is lower than 1 bar.

Make sure you have reset the boiler; The reset button is on the front of the boiler you will need to hold it for 1-3 seconds.

Make sure the gas main handle is open.

Call out a Qualified Engineer once the other five steps have been checked.

What to do as a Qualified Gas Engineer?

Here are a couple of steps to take that may resolve the E15 Fault “Gas Valve Error”:

Before taking the casing off the boiler

If you encounter the E15 error code on your Main Eco Compact boiler, a simple reset can often resolve temporary glitches. Locate the reset button or switch on the front of the boiler and press or toggle it to reset the system. Allow the boiler to restart and observe if the E15 error code persists. If the error code continues to appear, further troubleshooting may be required.

Check the Electricity: Electrical issues can sometimes trigger the E15 error code. Check the following components related to electricity:

  • Make sure the switch fuse that supplies electricity to the boiler is operating properly. Verify the fuse to make sure it hasn’t tripped.
  • Fuse on the PCB: The boiler’s printed circuit board (PCB) may have a fuse that is prone to blowing. Examine the PCB and verify the fuse’s integrity. Replace the blown fuse with a fresh one that has the same rating.
  • Connecting Wires: Check the wire that connects the boiler to the switch fuse. Keep an eye out for any damage indicators, such as fractures, tears, burns, or wounds. The cable needs to be fixed or replaced if there are any problems.

 

Check the Gas: Gas-related issues can also trigger the E15 error code. Take the following steps to ensure a proper gas supply:

Check the Gas Supply:

Step 1: To begin, ensure that the gas handle or valve responsible for supplying gas to your boiler is fully open. Additionally, examine the gas nipple at the mains to verify if the gas is flowing adequately. If you notice no gas flow or a poor gas flow, it’s crucial to promptly contact your gas provider or a skilled specialist to address the underlying issue.

Step 2: Measure Gas Pressure: Using a manometer, measure the gas pressure at the screw on the gas lever located at the bottom of your boiler. This straightforward gas pressure test allows you to determine whether the gas is entering the boiler at the recommended pressure level. If the measured gas pressure falls outside the recommended range, it may indicate an underlying problem with the gas supply or the gas valve itself.

 After taking the casing is off the boiler.

Wires: Inspect the wiring connections within the boiler. Look for any loose, broken, or burnt wires. Loose or disconnected wires can disrupt the communication and operation of various components, including the gas valve. If you notice any wiring issues, it’s advisable to seek professional assistance to properly address and repair them.

Leaks or Water: Carefully examine the fascia (front panel) of the boiler for any signs of leaks or water accumulation. Water entry into the boiler can cause damage to sensitive components, including the gas valve. Additionally, leaks may indicate a separate issue that needs to be resolved to ensure the proper functioning of the boiler. If you detect any leaks or water presence, it’s crucial to contact a qualified technician for further investigation and repairs.

To address the E15 fault code on your Main eco Compact boiler, it’s crucial to inspect the gas valve thoroughly. Follow these steps to assess and maintain the gas valve:

Step 1: Check for Blockages or Stuck Mechanism:

Examine the gas valve to ensure it is not blocked or stuck. If you notice any debris or obstruction, carefully clean it out of the gas valve. Blockages can impede the proper flow of gas and contribute to the E15 fault code. Clearing any obstructions will help restore the functionality of the gas valve.

Step 2: Test Gas Pressure with a Manometer:

Utilize a manometer to measure the pressure of the gas flowing through the gas valve. Attach the manometer to the screw on the gas valve and observe the pressure reading. Comparing the measured pressure to the recommended range will help determine if the gas is flowing at the appropriate level. Any deviations from the recommended range may indicate an issue with the gas valve or the gas supply.

Step 3: Isolate Gas and Check for Blockages:

To further investigate the gas valve, you can isolate the gas flow by using the bottom lever located underneath the boiler. This precautionary step ensures safety during maintenance. Once the gas is isolated, remove the gas valve for a more thorough examination. Check for any blockages or restrictions that may be affecting its performance. If blockages are found, clean or remove them as necessary to restore proper gas flow.

Step 4: Listen for Unusual Noises:

A faulty gas valve can sometimes produce unusual noises, such as clicking or hissing sounds. If you hear any strange sounds emanating from your boiler, it’s important to investigate further and consider the possibility of a gas valve issue. Unusual noises may indicate a malfunctioning or defective gas valve that requires attention and repair.

Gas Valve Wire Connection: 

  • Check that the wire connection is fully and securely inserted in the Gas Valve. 
  • Check that the wire connection is fully and securely inserted into PCB Board 
  • Check that the wire is not broken or burnt. 
  • Check the Voltage of the wire to see if it is sending the correct voltage to the gas valve (Check out our video on how to do a voltage test on a wire connection.) 
  • If the wire is fine and is giving the right voltage, could possibly be a PCB and may need replacing.

Ignition attempts: If you notice that the boiler is repeatedly attempting to ignite but fails to do so, it could be due to a malfunctioning gas valve, which is indicated by the E15 fault code also check that the spark electrode is clean so it is getting a good enough connection.

FAQ's

The E15 fault code on your Main eco Compact boiler indicates a gas valve error. To address this issue, you can perform some initial checks. Ensure the gas handle or valve supplying gas to the boiler is fully open. Examine the gas nipple at the mains to confirm gas flow. If necessary, measure the gas pressure using a manometer. Additionally, inspect the boiler for any visible abnormalities like loose wires or leaks. If these steps don’t resolve the issue, it’s best to seek professional assistance.

While some basic troubleshooting steps can be performed by homeowners, addressing the E15 fault code often requires professional expertise. Working with gas appliances can be dangerous, and it’s essential to prioritize safety. It is recommended to consult a qualified heating engineer or Main eco boiler service technician to accurately diagnose and repair the gas valve issue. They have the necessary skills, knowledge, and tools to ensure a safe and effective resolution.

Regular inspection and maintenance of the gas valve are crucial for the proper functioning of your boiler. The gas valve controls the flow of gas into the appliance, ensuring optimal performance and safety. Over time, debris, blockages, or mechanical issues can affect the valve’s operation, leading to faults like the E15 code. By conducting routine inspections and cleaning any obstructions, you can prevent potential problems, maintain efficiency, and prolong the lifespan of your boiler.

Remember, these FAQs are meant to provide general information, and for specific issues or concerns related to your Main eco Compact boiler and the E15 fault code, it’s always recommended to consult the manufacturer’s documentation or seek professional assistance.

Need help finding an engineer?

Book with us today for reliable and efficient service. If you need help getting an engineer for your heating or plumbing needs, Click the link below to schedule an appointment. Our experienced professionals are here to assist you.

Experience exceptional service that exceeds your expectations.

Need a boiler quote

Get a free quote, done today!

If you would like some further help. Please don’t hesitate to contact one of our dedicated staff members, they will give you the best advice they possibly can to help. 

Call us on: