Troubleshooting and Fixing a E09 Fault "No Gas Valve Connection"

Error on Your Main Eco Compact Boiler

Skip To:

A reliable and efficient boiler is essential for maintaining a comfortable living environment. However, encountering errors can disrupt the smooth operation of your heating system. One common issue that Main Eco Compact boiler owners may face is the “no gas valve connection” error. In this blog, we will explore the possible causes of this error and provide troubleshooting tips to help you resolve the issue and restore your boiler’s functionality

E09 Red Flags!

When encountering the E09 error code on a Main Eco Compact boiler, there are several red flags or indicators that can help you identify the issue. Here are some common red flags associated with the E09 error code:

  • No ignition or flame: The boiler fails to ignite or maintain a flame. You may notice that the burner does not ignite or that the flame goes out shortly after ignition.
  • Error code display: The E09 error code is usually displayed on the boiler’s control panel or digital display. This is an obvious red flag that something is wrong with the gas valve or flame detection system.
  • Boiler shutdown or lockout: The boiler may shut down automatically or go into a lockout state due to the E09 error code. This is a safety measure to prevent potential hazards and further damage to the system.
  • Audible clicking or sparking sounds: You might hear clicking or sparking sounds coming from the boiler when it attempts to ignite the burner. However, if the E09 error code is present, the ignition process is likely unsuccessful.
  • Error code persistence: If the E09 error code keeps reoccurring even after you have attempted to reset the boiler or perform basic troubleshooting steps, it indicates a persistent issue that requires further investigation.

If you notice any of these red flags in conjunction with the E09 error code, it is advisable to address the problem promptly. Take appropriate safety precautions, follow the troubleshooting steps below, and consider seeking professional assistance if needed to diagnose and resolve the issue effectively.

While the provided information can be attempted by homeowners, fixing the “no gas valve connection” error often requires a qualified gas engineer, specialised knowledge, and tools. Gas-related issues can be potentially dangerous, so it is crucial to prioritise safety. If you are QUALIFIED and confident in your skills and have experience working with heating systems, you can try the troubleshooting steps cautiously. However, if you are unsure or uncomfortable with handling gas-related repairs, it is best to leave it to the professionals to ensure a safe and accurate resolution.

Check out what your allowed to do:

E09 Troubleshooting Tips:

Check Gas Supply: The first step is to ensure that the gas supply to your boiler is turned on and that there is sufficient gas pressure. Verify that the gas isolation valve, usually located near the boiler, is fully open.

Verify Gas Valve Connections: Inspect all the connections between the gas valve and the boiler. Ensure that they are securely connected and not loose. If you find any loose connections, carefully tighten them to establish a proper connection.

Inspect Wiring: Examine the wiring connections between the gas valve and the boiler control board. Look for any loose or damaged wires. If you notice any issues, it is advisable to consult a professional heating engineer or contact the manufacturer’s customer support for guidance on repairing or replacing the wiring.

Reset the Boiler: Sometimes, a simple reset can resolve temporary glitches or communication errors. Turn off the power supply to your boiler, wait for a few seconds, and then turn it back on. This may help restore the gas valve connection.

If the troubleshooting steps mentioned above do not resolve the “no gas valve connection” error, it is recommended to seek professional assistance. A qualified heating engineer or the manufacturer’s customer support will have the expertise to diagnose and resolve the issue effectively. They may need to inspect the gas valve, control board, or other components to identify the underlying cause and implement the appropriate fix.

What can you do as a Homeowner?

Here are a couple of steps that you can take to resolve the E09 Fault “no gas valve connection” before having to call out a qualified gas engineer!

Make sure you have electricity to the boiler. Make sure the front screen is on the boiler and the boiler is switched on at the switched fuse.

Make sure the valves on the bottom of the boiler are open (With the Pipe = Open, Across the Pipe = Closed) (Except the Combi Filling loop leave closes)

Check the boiler has the correct pressure, This is normally 1 bar – 1.5 bar of pressure. 

(Check out our video on how to repressurise your main eco compact boiler) if the boiler is lower than 1 bar

Picture of the Combi Filling loop on the baxi main Combi Filling Loop

Make sure you have reset the boiler; The reset button is on the front of the boiler you will need to hold it for 1 to 3 seconds.

Picture of the Reset button the Baxi main eco compact boiler

Make sure the gas main handle is open.

Call out a Qualified Engineer once the other five steps have been checked.

What to do as a Qualified Gas Engineer?

Here are a couple of steps that you can take to resolve the E09 Fault “no gas valve connection” as a qualified gas engineer!

Before taking the casing off the boiler

Reset the Boiler:

If you encounter the E09 error code on your Main Eco Compact boiler, a simple reset can often resolve temporary glitches. Locate the reset button or switch on the front of the boiler and press or toggle it to reset the system. Allow the boiler to restart and observe if the E09 error code persists. If the error code continues to appear, further troubleshooting may be required.

Check the Electricity:

Electrical issues can sometimes trigger the E09 error code. Check the following components related to electricity:

Switch Fuse: Ensure that the switch fuse supplying electricity to the boiler is functioning correctly. Check if the fuse is intact and not tripped.

Fuse on the PCB: The Printed Circuit Board (PCB) of the boiler may have a fuse that could be blown. Inspect the PCB and check if the fuse is intact. If the fuse is blown, replace it with a new one of the same rating.

Wire Connections: Examine the wire connecting the switch fuse to the boiler. Look for any signs of damage, such as breaks, tears, burns, or cuts. If you notice any issues with the wire, it should be repaired or replaced.

Check the Gas:

Gas-related issues can also trigger the E09 error code. Take the following steps to ensure a proper gas supply:

Gas Handle: Verify that the gas handle or valve supplying gas to the boiler is fully open.

Gas Nipple at the Mains: Check the nipple at the mains to ensure it is releasing gas. If there is no gas flow or a weak gas flow, contact your gas provider or a qualified professional to address the issue.

Gas Pressure Test: Use a manometer to measure the gas pressure at the screw on the gas lever at the bottom of the boiler. This test will help determine if the gas is reaching the boiler at the correct pressure. If the gas pressure is outside the recommended range, it may indicate a problem with the gas supply or gas valve.

Check the Water:

Water pressure issues can also contribute to the E09 error code. Follow these steps to ensure proper water pressure:

Pressure Check: Verify that the pressure on the boiler’s pressure gauge is set to around 1 bar. If the pressure is too low, refer to the boiler’s manual for instructions on how to refill or repressurize the system.

Open Valves: Ensure that all valves under the boiler, are fully open to allow for proper water flow.

 After taking the casing is off the boiler.

Check the Gas Valve:

One of the first steps in troubleshooting the E09 error code is to ensure that the gas valve is functioning properly. To do this, you can use a manometer to test the gas pressure at the screw on the gas valve. This will help determine if the correct amount of gas is being delivered to the boiler. If the gas pressure is not within the recommended range, it may indicate a problem with the gas valve or gas supply. In such cases, it is advisable to repair or replace the gas valve.

Inspect the Wire Connection:

The wire connection between the gas valve and the PCB (Printed Circuit Board) is crucial for proper communication and operation of the boiler. It’s important to check both sides of the wire connection to ensure they are securely connected. Look for any breaks or damage in the wire that could be interrupting the flow of electrical signals. If the wire appears damaged or worn out, it should be replaced. To further test the wire, you can perform a voltage test using a multimeter to check if it is carrying the correct voltage. You can find detailed instructions on how to conduct a voltage test on a wire connection in our video tutorial.

Consider Replacing the PCB:

If the gas valve and wire connection appear to be in good condition, but the E09 error code persists, it may indicate a faulty PCB. The PCB is responsible for controlling various functions of the boiler, including the gas valve. If the PCB is malfunctioning or not communicating properly with the gas valve, it can trigger the E09 error code. In this case, replacing the PCB could be necessary. It is recommended to contact the manufacturer’s customer support to diagnose the issue accurately and determine if a PCB replacement is required.

Remember, when dealing with electrical components or gas-related repairs, it’s crucial to prioritize safety and consult professionals or qualified technicians if you are uncertain or uncomfortable performing the tasks yourself. They have the expertise and knowledge to ensure proper diagnosis, repair, or replacement, reducing the risk of further damage or hazards.

FAQ's

The E09 error code indicates a “no gas valve connection” error, signalling a problem with the gas valve or its connection to the boiler. It can cause issues with ignition, flame stability, and heating operation.

While some basic troubleshooting steps can be attempted by homeowners, resolving the E09 error code often requires specialized knowledge and tools. Gas-related repairs can be potentially dangerous, so it is advisable to seek professional assistance from a qualified heating engineer or contact the manufacturer’s customer support.

If the E09 error code continues to appear after resetting the boiler, it indicates a persistent issue that requires further investigation. It is recommended to check the gas valve connections, inspect wiring for any damages, test gas pressure, and ensure proper water pressure. If the problem persists, consult a professional for a thorough diagnosis and resolution.

To check the gas pressure, you can use a manometer. Attach the manometer to the screw on the gas lever at the bottom of the boiler and observe the pressure reading. Consult the boiler’s manual or contact a professional to determine the recommended gas pressure range for your specific model.

Regular maintenance is essential for optimal boiler performance. Some preventive measures include cleaning or replacing filters, inspecting and tightening gas valve connections, checking and adjusting water pressure, and scheduling annual maintenance with a qualified heating engineer. These steps can help prevent common issues that may lead to the E09 error code.

Need help finding an engineer?

Book with us today for reliable and efficient service. If you need help getting an engineer for your heating or plumbing needs, Click the link below to schedule an appointment. Our experienced professionals are here to assist you.

Experience exceptional service that exceeds your expectations.

Need a boiler quote

Get a free quote, done today!

If you would like some further help. Please don’t hesitate to contact one of our dedicated staff members, they will give you the best advice they possibly can to help. 

Call us on: