Troubleshooting and Fixing Fault Code F83 "Dry Fire"

on your Glow-Worm EasiCom Boiler

A dry fire in a boiler occurs when the heating system operates without sufficient water. This can lead to severe damage and compromise the safety of the appliance. If you encounter an F83 fault code on your Glow-Worm EasiCom Boiler, it indicates a dry fire situation. In this blog post, we will explore the details of this fault, identify warning signs, provide troubleshooting tips, and guide homeowners and engineers on how to effectively resolve the issue.

Skip To:

Understanding Dry Fire

The F83 fault code on the Glow-Worm EasiCom Boiler points to a dry fire, which means the boiler has operated without adequate water supply. Dry firing can cause significant damage to the heat exchanger, burner, and other boiler components, as well as pose a safety risk.

F83 Red Flags!

If you suspect an F83 fault on your Glow-Worm EasiCom Boiler, watch out for the following warning signs:

  1. Displayed error code: The boiler’s display shows the F83 fault code or an associated error message.
  2. Unusual noises: You may hear banging, clanging, or other abnormal noises coming from the boiler during operation.
  3. Loss of heating: The boiler fails to provide heat to the heating system, leaving your home without adequate warmth.
  4. Overheating smell: You may detect a burning or overheating smell coming from the boiler.
  5. System shutdown: The boiler shuts down to prevent further damage or as a safety measure.

Check out what your allowed to do:

Troubleshooting Tips:

If you encounter an F83 fault on your Glow-Worm EasiCom Boiler, try the following troubleshooting tips before seeking professional assistance:

  1. Check water supply: Ensure that the boiler’s water supply is sufficient, and the water pressure is within the recommended range. If the pressure is low, check the water inlet valve and ensure it is fully open.
  2. Inspect the filling loop: Examine the filling loop, which is responsible for maintaining the water level in the boiler, for any leaks, blockages, or malfunctions. Repair or replace the filling loop components as necessary.
  3. Verify the system pressure: Use the pressure gauge on the boiler to check the system pressure. If it is too high or too low, it may indicate a problem with the pressure relief valve or other components. Contact a professional engineer for further investigation.
  4. Reset the boiler: Attempt to reset the boiler by turning it off, waiting for a few seconds, and then turning it back on. This may clear any temporary faults and allow the boiler to resume normal operation. However, professional attention is still necessary to ensure there is no damage from the dry fire.
  5. Contact customer support or a qualified engineer: Reach out to Glow-Worm’s customer support or a qualified engineer for further guidance. They can help over the phone or via email and assess the extent of the damage caused by the dry fire.

What can you do as a Homeowner?

As a homeowner, you can take the following steps to address the F83 fault on your Glow-Worm EasiCom Boiler:

  1. Perform basic troubleshooting: Follow the troubleshooting tips mentioned above to see if you can resolve the issue independently. Check the water supply, inspect the filling loop, verify the system pressure, reset the boiler, and contact customer support or a qualified engineer for assistance.
  2. Schedule a service visit: Due to the potential damage caused by a dry fire, it is crucial to schedule a service visit with a qualified engineer as soon as possible. They can assess the extent of the damage, implement necessary repairs, and ensure the safe operation of your boiler.
  3. Check warranty coverage: Review your warranty documentation or contact Glow-Worm customer support to determine if the F83 fault is covered. If it is covered, the manufacturer may arrange for a technician to address the issue at no cost to you.
  4. Preventive measures: To prevent dry fires in the future, ensure that the boiler’s water supply is always sufficient, and the water pressure is within the recommended range. Regularly check and maintain the filling loop and other components related to the water supply.

What to do as a Qualified Gas Engineer?

As an engineer, follow these steps to diagnose and resolve the F83 fault on the Glow-Worm EasiCom Boiler:

  1. Inspect the water supply: Verify that the boiler is receiving an adequate water supply and the water pressure is within the recommended range. Check the water inlet valve and associated components for any blockages, leaks, or malfunctions.
  2. Examine the filling loop: Inspect the filling loop and its components, such as isolation valves and check valves. Look for leaks, blockages, or faulty connections. Repair or replace any damaged or faulty parts.
  3. Test the pressure relief valve: Check the pressure relief valve to ensure it is functioning correctly. Test its operation and verify that it releases excess pressure when needed. Replace the pressure relief valve if it is faulty or not working as intended.
  4. Inspect the heat exchanger and other components: Assess the heat exchanger and other boiler components for damage resulting from the dry fire. Look for signs of warping, cracking, or other visible abnormalities. Replace any damaged components.
  5. System evaluation and testing: Conduct a thorough evaluation of the entire heating system to ensure there are no additional issues caused by the dry fire. Test the boiler’s operation, including the water supply, pressure, and heating performance, to confirm that it is functioning properly.

FAQ's

It is strongly advised not to continue using the boiler with the F83 fault, as dry firing can cause severe damage to the heat exchanger and other components. Continuing to operate the boiler may lead to further malfunctions, safety risks, and potential additional costs.

The time required to resolve the F83 fault depends on the extent of the damage caused by the dry fire. It may involve component replacements and thorough testing. The engineer will be able to provide an estimate based on the specific circumstances.

Warranty coverage varies depending on the manufacturer and the specific terms of your warranty agreement. Check the warranty documentation provided by Glow-Worm or consult customer support to determine if the F83 fault is covered.

Conclusion

Remember, dry firing is a serious issue that requires prompt attention from a qualified engineer. If you suspect a dry fire, it is crucial to take immediate action to prevent further damage and ensure the safe operation of your boiler.

Need help finding an engineer?

Book with us today for reliable and efficient service. If you need help getting an engineer for your heating or plumbing needs, Click the link below to schedule an appointment. Our experienced professionals are here to assist you.

Experience exceptional service that exceeds your expectations.

Need a boiler quote

Get a free quote, done today!

If you would like some further help. Please don’t hesitate to contact one of our dedicated staff members, they will give you the best advice they possibly can to help. 

Call us on: